If the parameters set in the current program are outside the allowable range of the
connected screwdriver, the following screen will appear:
To resolve the error, select a program previously configured for the connected screwdriver
model, or enter the main menu to modify the parameter out of range for the current
program.
The “Program parameter error” messages can be the following:
TorqueTargOverMax
Target torque higher than the allowed limit for the
screwdriver.
SpeedTargOverMax
Target speed higher than the limit allowed for the
screwdriver.
SpeedTargUnderMin
Target speed less than the limit allowed for the
screwdriver.
DownshiftTorqueOverTarg
The fast phase torque setting is higher than the final target
torque.
DownshiftSpeedOverMax
The speed of the slow phase of this program is higher than
the maximum allowed by the screwdriver.
DownshiftSpeedUnderMin
The speed of the slow phase of this program is less than the
minimum allowed by the screwdriver.
TorqueMaxOverMaxLim
In angle control: the maximum torque set in the program is
above the limit of the screwdriver.
In torque control: the maximum torque set in the program
is higher than 20Nm.
TorqueMaxUnderMinLim
In angle control: the maximum torque set in the program is
equal or lower than the minimum limit of the screwdriver.
In torque control: The maximum torque set in the program
is equal or lower than the target torque already set.