Vers. 062721 9
TOOL connector
To connect a KDS series screwdriver. Take care to respect the alignment tabs on the
connector. See “Installation of KDS screwdriver” section for instructions on connecting the
screwdriver.
CN1 connector
Reserved for servicing the unit and upgrading the firmware.
CN2 male serial connector
To connect with a compatible barcode scanner, such as Kolver Barcode P/N 020050, serial
printers such as Kolver PRNTR1, or serial terminals (PC/PLCs).
CN4 female serial connector
To connect with Kolver accessories SWBX88/CBX880, serial printers such as Kolver
PRNTR1, or serial terminals (PC/PLCs).
CN3 I/O connector
To connect with 24V I/O functionality such as PLCs, pedals/buttons, LEDS, etc. Refer to
REMOTE CONTROL INTERFACES chapter.
CN5 ethernet connector RJ45
To connect using MODBUS TCP, Open Protocol, or K-Expand on any compatible device or
software (PLCs, PCs, etc). Refer to REMOTE CONTROL INTERFACES chapter.
USB mini B
To connect using K-Expand software. Refer to K-EXPAND software chapter.
USB A
Plug in a FAT32 formatted flash drive to automatically save screwdriving results and backup
all settings. Refer to the “Retrieving and storing the screwdriving results” and “USB menu”
sections.
Installation of KDS screwdriver
Cable connection and part numbers
The KDS screwdriver series require one of the following cables:
- 2.5m male/female cable (code 250064)
- 2.5m male/female cable with strain relief (code 250064/H)
- 5.0m male/female cable (code 250564)
- 5.0m male/female cable with strain relief (code 250564/H)