OPERATION
DETAILED CONTROLS AND GAUGES
FUSIBLE LINK
If any of the following problems have occurred, there is probably a
disconnection in the fusible link. Open the battery room door on
the left side of the machine, and check and replace.
If the starting motor does not turn even when the starting switch
is turned to the START position, there is probably a
disconnection in the fusible link (1).
If the battery is discharged, there is probably a disconnection in
the fusible link (2).
In cold weather, if the starting switch is turned to the HEAT
position and preheating is carried out, but the engine is difficult
to start, there is probably a disconnection in fusible link (3).
REMARK
A fusible link refers to the large-sized fuse wiring installed in the
high current flow portion of the circuit to protect electrical
components and wiring from burning, in the same way as an
ordinary fuse.
No. Capacity Circuit name Connector No. Part No.
(1) 45A Permanent power supply F02
20T-06-81230
(1) 45A Permanent power supply F03
(2)
50A Alternator (35A)
F05
417-06-22610
120A Alternator (60A) (if equipped)
421-06-22830
(3) 120A Preheating F06
3 - 109