34
322217/G
TurningoffthecNODE
Thiswillleaveyouwiththetransponderturnedoffandnotusingupthebattery.
Prerequisites
WARNING
Removethebatterywhenstoringthetransponderforalongerperiod(months).
Procedure
1Pullouttheplasticlockingcordthatsecuresthetransducerinplace.
2Removethetransducer.
3Removethebattery.
4Switchtheon/offswitchinsidethetoptooff.
5Replacethetop.
6Insertthelockingcordbypushingitsidewaysaroundthebody.
Pre-deploymentchecks
Beforedeployingthetransponder,itisimportanttodothefollowingcheckstomake
suretheoperationgoessmoothly.
Prerequisites
Beforedeployingthetransponder,itisimportanttodothefollowingcheckstomake
suretheoperationgoessmoothly.
Procedure
1Recordthetransponderserialnumberandchannels.
2Makesuretheventscrewisclosed.
KongsbergcNODEInstructionManual