EasyManua.ls Logo

Kongsberg cNODE Maxi - Operating Procedures

Kongsberg cNODE Maxi
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
46
322217/G
5Takeoutthebattery,seetheemergencyprocedureforopeningatransponderwitha
possibledefectbattery.
Openingatransponderwithdefect/possiblydefectbattery,page45
Handlingatransponderwithanopenrelief
valve
Alwaysreadtheemergencyproceduresbeforehandlinglithiumbatteries.
Procedure
1Evacuateallunnecessarypeople.
2UseafullfacemaskwithminimumBE-lter,andprotectiveequipmentmadeof
rubberorplastic.
3Fastenthetranspondertoaropeoracraneandimmerseintheseafor24hours
orpermanent.Ifthismethodisimpossible,theunitcanbecooledwithcopious
amountsofcoldwaterusingarehose.
4Repeatthisuntilnogasescomeoutthereliefvalveandthetemperatureislow
andstable.
5Takeoutthebattery,seetheemergencyprocedureforopeningatransponderwitha
possibledefectbattery.
Openingatransponderwithdefect/possiblydefectbattery,page45
6Washouttheresiduesfromthechemicalreactionwithwater.
Handlingheatedorwarmbatteries
Alwaysreadtheemergencyproceduresbeforehandlinglithiumbatteries.
Procedure
1Evacuateallunnecessarypeople.
2Fastenthebatterytoaropeoracraneandimmerseintheseafor24hoursor
permanent.Ifthismethodisimpossible,theunitcanbecooledwithcopious
amountsofcoldwaterusingarehose.
3Washouttheresiduesfromthechemicalreactionwithwater.
KongsbergcNODEInstructionManual

Table of Contents