3Pressthepressurereliefvalvein,toconrmitisushwiththeendcap.
4Checkthefollowingifaoatingcollarisusedwiththetransponder:
aMakesurethetransponderisproperlyattachedtotheoatingcollar.
bMakesuretheweightisproperlyattachedtotherelease.
5PerformanacoustictestusingaTransponderTestandConguration(TTC)unit:
aInterrogatethetransponder.
bReadbatterystatusandconrmthatitwilllastfortheupcomingoperation.
cReadthepowersettingandconrmitiscorrectfortheupcomingoperation.
Changingbetweenresponderand
transpondermode
Thetranspondercanalsobeusedasaresponderunit.
Prerequisites
Thetranspondermustbechargedbeforeuse.
BydefaultwhenthecNODEisturnedonitisintranspondermode.
Thesignalinputfortheresponderfunctionmustbebetween2and6mswithapositive
pulseof5to24V .
Procedure
1Whenrespondertriggersignalsarereceived,themodeisautomaticallychanged
toresponder.
2Oncetherespondertriggersignalsstop,itwilltake1minutebeforethecNODE
changesautomaticallybacktotranspondermode.
Gettingstarted