322217/G
53
Note
Readthelithiumbatteriessafetyprocedurebeforehandlingbatteries.
Donotconnectthe+and–electrodesonthebatterieswithmetalorwire..
Procedure
1Pullouttheplasticlockingcordthatsecuresthetransducerinplace.
2Removethetransducer.
3Removethespentbattery.
4Insertthenewbattery.
Insertingthebatteryatananglemakesthiseasier.Pressrmlytomakesurethe
batteryisproperlyinserted.
5Placeabagofdrysilica-geldesiccantonthetopofthebattery.
6Switchtheon/offswitchinsidethetoptoon.
7Replacethetop.
Makesurethealignmentmarksmeet.
8Insertthelockingcordbypushingitsidewaysaroundthebody.
Result
Abuzzcanbeheardwithin25secondsasaconrmationthatthetransponderisactivated.
Maintenance