Kramer Electronics Ltd.
VP-440 Protocol 3000
48
BUILD-DATE
Functions
Permission
Transparency
Set:
BUILD-DATE
End User
-
Get:
-
-
-
Description
Syntax
Set:
Read device build date
#BUILD-DATE?
Get:
-
-
Response
~nn@BUILD-DATEdatetime␍␊
Parameters
date Format: YYYY/MM/DD where YYYY = Year, MM = Month, DD = Day
time Format: hh:mm:ss where hh = hours, mm = minutes, ss = seconds
DISPLAY?
Functions
Permission
Transparency
Set:
-
-
-
Get
DISPLAY?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get output HPD status
#DISPLAY?P1
Response
~ nn @DISPLAYP1␍␊
Parameters
P1 (Output number) 0=HDMI; 1=HDBaseT
Response triggers
After execution, response is sent to the com port from which the Get was received
Response is sent after every change in output HPD status ON to OFF
Response is sent after every change in output HPD status OFF to ON and ALL parameters (new EDID,
etc.) are stable and valid

Other manuals for Kramer VP-440