I - 7
General Information
1.5 Connection Requirements, Tractor
Brake connections:
For Big Pack Baler with:
brake activated by compressed air Dual-line brake system required
hydraulically activated brake (6) Connection for hydraulic brake system required
(max. operating pressure 120 bar)
Electrical connections:
Lighting for the Big Pack Baler 7-pin socket DIN ISO 1124
Power supply for the electronic 2-pin socket
control system (direct battery connection required for continuous power)
Baler with 65 km/h approval ABS socket
Hydraulic connections:
Depending of the design of your Big Pack Baler, the following connections are possible:
Depending on version:
Raising the pick-up (1) Single-action control valve (yellow protective cap)
Locking the steering axle (7) Single-action control valve (green protective cap)
Support base (hydraulic) Double-action control valve (green protective cap)
Basic electronics/medium electronics:
Hinging blade bar (2) Double-action control valve (red protective cap)
(2A retract blade bar), (2B extend blade bar)
Residual bale ejector/roller chute (8) Double-action control valve (blue protective cap)
(8A forward motion) , (8B reverse motion)
Comfort version electronics:
Supply control block (4) Single-action control valve (NW 15) (red protective cap)
Return control block (5) Return tank (NW 18) (blue protective cap)
Load sensing line *(3) LS connection (NW 12) (blue protective cap)
* Only for tractors with load-sensing hydraulics
5
4
1
2A
3
2B
BPXC0232
8B
8A
6
7