2FT
1-5-4
Paper
conveying
section
22 Multiple sheets in the
drawer 2 (first paper
feeder)
The registration switch (RSW) does not turn off within 4976 ms
of registration switch (RSW) turning on.
The registration switch (RSW) does not turn off within 2189 ms
of drawer paper feed clutch 1 (DPFCL1) turning on.
23 Multiple sheets in the
drawer 3* (second paper
feeder)
The drawer feed switch 1 (DFSW1) does not turn off within
4976 ms of drawer feed switch 1 (DFSW1) turning on.
The drawer feed switch 1 (DFSW1) does not turn off within
1961 ms of drawer paper feed clutch 2 (DPFCL2)* turning on.
24 Multiple sheets in the
drawer 4* (third paper
feeder)
The drawer feed switch 2 (DFSW2)* does not turn off within
4976 ms of drawer feed switch 2 (DFSW2)* turning on.
The drawer feed switch 2 (DFSW2)* does not turn off within
1961 ms of drawer paper feed clutch 3 (DPFCL3)* turning on.
Transfer
section
30 Misfeed in registration/
transfer section
The registration switch (RSW) does not turn off within 1843 ms
of drawer feed switch 1 (DFSW1) turning on.
The registration switch (RSW) does not turn off within 1843 ms
of drawer feed switch 1 (DFSW1) turning off.
The registration switch (RSW) does not turn off within 1386 ms
of duplex paper conveying switch (DUPPCSW1)* turning on.
Fixing
section
40 Misfeed in the fixing
section (paper feed from
bypass tray)
The exit switch (ESW) does not turn on within 2378 ms of the
registration motor (RM) turning on.
41 Misfeed in the fixing
section (paper feed from
drawer)
The exit switch (ESW) does not turn on within 2378 ms of the
registration motor (RM) turning on.
42 Misfeed in the fixing
section (paper feed from
first paper feeder)
The exit switch (ESW) does not turn on within 2378 ms of the
registration motor (RM) turning on.
43 Misfeed in the fixing
section (paper feed from
second paper feeder*)
The exit switch (ESW) does not turn on within 2378 ms of the
registration motor (RM) turning on.
44 Misfeed in the fixing
section (paper feed from
third paper feeder*)
The exit switch (ESW) does not turn on within 2378 ms of the
registration motor (RM) turning on.
45 Misfeed in the fixing
section (paper feed from
duplex section*)
The exit switch (ESW) does not turn on within 2378 ms of the
registration motor (RM) turning on.
Exit section 50 Misfeed in the exit section The exit switch (ESW) does not turn off within 2378 ms of the
registration switch (RSW) turning off.
The exit switch (ESW) does not turn on within 2378 ms of the
registration motor (RM) turning on.
51 Misfeed in the job
separator*
The job separator eject switch (JBESW)* does not turn on
within 1614 ms of feedshift switch (FSSW) turning on.
The job separator eject switch (JBESW)* does not turn off
within 1614 ms of feedshift switch (FSSW) turning off.
The job separator eject switch (JBESW)* does not turn off
within 1614 ms of feedshift switch (FSSW) turning off.
*: Optional.
Section Jam code Description Conditions