2FT-1
2-4-9
Periodic maintenance procedures
Section
Maintenance
part/location
Method Maintenance cycle Points and cautions Page
Test copy and
test print
Perform at the maxi-
mum copy size
Test copy Every service
Section
Maintenance
part/location
Method Maintenance cycle Points and cautions Page
Paper feed
section
Paper feed pulley
Clean or replace Every 300,000 counts
Clean with the alcohol. 1-6-5
Separation pulley
Clean or replace Every 300,000 counts
Clean with the alcohol. 1-6-3
Forwarding pulley
Clean or replace Every 300,000 counts
Clean with the alcohol. 1-6-5
Drawer paper feed pulley
Clean or replace Every 300,000 counts
Clean with the alcohol. 1-6-9
Drawer separation pulley
Clean or replace Every 300,000 counts
Clean with the alcohol. 1-6-8
Drawer forwarding pulley
Clean or replace Every 300,000 counts
Clean with the alcohol. 1-6-9
Bypass paper feed pulley Clean or replace Every 300,000 counts
Clean with the alcohol. 1-6-13
Bypass separation pad
Clean or replace
- Clean with the alcohol. 1-6-13
Left registration roller
Clean or replace Every 300,000 counts Clean with alcohol or a dry cloth.
1-6-15
Right registration roller Clean
Every 300,000 counts Clean with alcohol or a dry cloth.
Registration cleaner
Clean or replace Every 300,000 counts
Vacuum. 1-6-15
Feed roller
Clean or replace
- Clean with the alcohol. 1-6-7
Feed pulley
Clean or replace
- Clean with alcohol or a dry
cloth.
Section
Maintenance
part/location
Method Maintenance cycle Points and cautions Page
Optical section Slit glass Clean
Every 300,000 counts
Clean with a dry cloth.
Contact glass Clean
Every 300,000 counts
Clean with alcohol and then a
dry cloth.
Mirror 1 Clean -
Clean with alcohol and then a
dry cloth only if vertical black
lines appear on the copy image.
Mirror 2 and mirror 3 Clean -
Clean with alcohol and then a
dry cloth only if vertical black
lines appear on the copy image.
Lens Clean -
Clean with alcohol and then a
dry cloth only if vertical black
lines appear on the copy image.
Reflector Clean -
Clean with alcohol and then a
dry cloth only if vertical black
lines appear on the copy image.
Exposure lamp
Clean or replace
- Replace if an image problem
occurs or after the exposure
lamp does not turn on.
1-6-22
Optical rail Grease - Check noise and shifting and
then apply scanner rail grease
EM-50L..
Original size detection
sensor
Clean -
Clean with alcohol or a dry cloth.
Laser scanner unit Clean
Every 300,000 counts Clean with alcohol.

Table of Contents