2FT
1-5-33
(18)Image center does not align with
the original center.
Causes
1. Misadjusted center line of image printing.
2. Misadjusted scanner center line.
3. Original placed incorrectly.
Causes Check procedures/corrective measures
1. Misadjusted center line of image printing.
Readjust the center line of image printing (see page 1-6-18).
2. Misadjusted scanner center line.
Readjust the scanner center line (see page 1-6-36).
3. Original placed incorrectly.
Place the original correctly.