2FT-1
1-5-25
C8180 Finisher* rear side registration motor
problem
If the rear side registration home position
sensor is on in initialization, the sensor
does not turn off within 570 ms of starting
initialization.
If the rear side registration home position
sensor is off in initialization, the sensor
does not turn on within 2880 ms of start-
ing initialization.
The rear side reg-
istration motor con-
nector makes poor
contact.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
remedy or replace the cable.
The rear side reg-
istration motor mal-
functions.
Replace the rear side registration motor and
check for correct operation.
The rear side reg-
istration home
position sensor
connector makes
poor contact.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
remedy or replace the cable.
The rear side reg-
istration home
position sensor
malfunctions.
Replace the rear side registration home
position sensor and check for correct opera-
tion.
Defective finisher
main PCB.
Replace the finisher main PCB and check
for correct operation.
C8190 Finisher* trailing edge registration
motor problem
If the trailing edge registration home
position sensor is on in initialization, the
sensor does not turn off within 570 ms of
starting initialization.
If the trailing edge registration home
position sensor is off in initialization, the
sensor does not turn on within 4550 ms
of starting initialization.
The trailing edge
registration motor
connector makes
poor contact.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
remedy or replace the cable.
The trailing edge
registration motor
malfunctions.
Replace the trailing edge registration motor
and check for correct operation.
The trailing edge
registration home
position sensor
connector makes
poor contact.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
remedy or replace the cable.
The trailing edge
registration home
position sensor
malfunctions.
Replace the trailing edge registration home
position sensor and check for correct opera-
tion.
Defective finisher
main PCB.
Replace the finisher main PCB and check
for correct operation.
C8210 Finisher* front stapler problem
The front stapler home position sensor
does not change state from nondetection
to detection within 200 ms of the start of
front stapler motor counterclockwise (for-
ward) rotation.
During initialization, the front stapler
home position sensor does not change
state from non-detection to detection
within 600 ms of the start of front stapler
motor clockwise (reverse) rotation.
The front stapler
connector makes
poor contact.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
remedy or replace the cable.
The front stapler
malfunctions.
a) The front sta-
pler is blocked with
a staple.
b) The front sta-
pler is broken.
a) Remove the front stapler cartridge, and
check the cartridge and the stapling section
of the stapler.
b) Replace the front stapler and check for
correct operation.
Defective finisher
main PCB.
Replace the finisher main PCB and check
for correct operation.
*: Optional.
Code Contents
Remarks
Causes Check procedures/corrective measures