LAUNCH
X-431 Module S2 User Manual
5
Fixed frequency simulation Support
Predefined waveform simulation Support
Hand-drawn waveform
simulation
Support
Signal generator interface 2
External power supply port 1
Solenoid interface 2
Multimeter interface 2
Working temperature
0~50
Storage temperature
-30~70
Multimeter:
Parameter Range
DC voltage 0V~700V
AC voltage 0V~700V
Resistance 0Ω~40MΩ
Capacitance 0F~100uF(maximum 30s measurement time)
Diode 0V~1.5V
Continuity detection Sounds below 30Ω