Description of fields
Field Option Description
Segm Selectable list Segment number. Includes the misclosure
segment, if applicable.
CumL Selectable list Cumulation of the segment lengths. Changes
with the current number of segments.
Includes the misclosure segment length if
applicable.
ΔHz Display only Horizontal direction from the measured point
to the stake out point. Positive if the tele-
scope must be turned clockwise to the stake
out point.
D Display only Horizontal distance from the measured point
to the stake out point. Positive if the stake
out point is further away than the measured
point.
D Display only Height difference from the measured point to
the stake out point. Positive if the stake out
point is higher than the measured point.
ΔL Display only Longitudinal distance from the measured
point to the stake out point. Positive if stake
out point is further away than the measured
point.
ΔO Display only Perpendicular distance from the measured
point to the stake out point. Positive if stake
out point is to the right of the measured
point.
The following are important messages or warnings that may appear.
Messages
Description
Baseline too short! Base line is shorter than 1 cm. Choose base
points such that the horizontal separation of
both points is at least 1 cm.
Coordinates invalid! No coordinates or invalid coordinates for a
point. Ensure that points used have at least
Easting and Northing coordinates.
Recording to interface! Data Output is set to Bluetooth in the
Data Settings Menu. To be able to success-
fully start reference line, Data Output must
be set to Internal Memory.
•
Either, press Meas to measure and record.
•
Or, press ESC to return to the Define Line Segment screen and from
there, press Back to return to the Reference Line screen.
•
Or, continue selecting ESC to exit the app.
Messages
Next step