5 Settings
5.1 Work Settings
1. Select Settings from the Main Menu.
2. On the General page, select Work.
Description of fields
Field Option Description
Trigger Key
1
Quick key programmable with one of the
functions:
Off The trigger key is deactivated.
Meas Sets the trigger key with the same function
as Meas.
Dist Sets the trigger key with the same function
as Dist.
Store Sets the trigger key with the same function
as Store.
USER Key 1
USER Key 2
Selectable list Configures the / keys with a function
from the Favourites menu.
Refer to "8 Favourites".
Tilt Correct Off Tilting compensation deactivated.
On 2-axis compensation. Vertical angles refer to
the plummet line and the horizontal direc-
tions are corrected by the standing axis tilt.
For corrections depending on the Hz Corr.
setting, refer to the table "Tilt and horizon-
tal corrections".
☞
If the instrument is used on an unstable base, for
example a shaking platform or ship, the compen-
sator should be deactivated. This avoids the com-
pensator drifting out of its measuring range and
interrupting the measuring process by indicating
an error.
Hz Corr. On Horizontal corrections are activated. For nor-
mal operation the horizontal correction
should remain active. Each measured hori-
zontal angle will be corrected, depending on
the vertical angle.
For corrections depending on the Tilt Cor-
rect setting, refer to the table "Tilt and hori-
zontal corrections".
Off Horizontal corrections are deactivated.
Line1 Fixed to Point ID Shown on a page in Sur-
vey.
Line2 to
Line14
The settings define the parameters shown on
a page in Survey.
Access