Partial milk collection button
(3)
Push and hold the button for 2 seconds to start or stop the partial milk
collection procedure for the selected main tank:
Green LED flashes: start/stop tank driver procedure requested
Green LED is on: system is ready to partially empty the main tank
Main tank valve button (4) Push the button to open or close the valve of the selected main tank:
Open the valve when the tank can be (partially) emptied. The green LED
is on when the valve is open.
Close the valve when the tank is (partially) empty. The green LED goes
off when the valve is closed.
Cluster selection button (5) The LEDs show the status of the cluster(s):
Green LED is on: the cluster is in operation
Green LED flashes: the cluster is not in operation
Push the button to select a cluster (A, B, C or D) to see the twin filter status
(6):
Green LED is on: the cluster is selected
After 10 seconds the LEDs return to the cluster status indication
Twin filter reset button (6) Push the button after a filter element has been replaced to identify that the
filter is clean:
Green LED is on: the related filter is in use
Red LED is on: the related filter is dirty and not in use
Alarm buzzer mute button (7) Push the button to mute the buzzer sound for 10 minutes, when an alarm
with buzzer sounds is generated:
Red LED is on: there is/are active alarm(s)
Push and hold the button until the LED goes off to clear the list of active
alarms.
Status LED (8)
Green LED is on: the CRS M3 is in operation and operates correctly
Green LED flashes: the CRS M3 is in error state
4.2.2 Extension Cabinet
The control panel on the extension cabinet has one indicator LED:
Description 4-3