4.4.4 Twin Filter (optional)
The twin filter (optional) has two filters. The CRS M3 automatically changes
from one filter to the other filter, during the cluster cleaning (when the hot
cleaning with chemicals starts). This gives more time to replace the used
filter and the cluster can stay in full operation. The used filter must be
replaced in between two scheduled cluster cleanings. All the robot units in
one cluster are connected to one twin filter.
Figure 6. Twin filter overview
KEY:
1. Twin filter brackets - 2. Milk outlet - 3. Bracket clamps - 4. Twin filter - 5. Milk inlet
The LEDs on the CRS M3 cabinet show status of the twin filter:
Figure 7. Twin filter status LEDs
LEDs Explanation
Off for both filters both filters are clean and not in use (or twin filter is not
installed)
Off for one filter The related filter is clean
Red The related filter is used and must be replaced
Green The related filter is currently in use
4.4.5 Precooler (optional)
The precooler cools down the milk during transport to the milk tank. Cooling
water flows through a heat exchanger and cools down the warm milk that
comes from the robot units. The precooler makes sure that:
4-8 Description