5. OPERATING INSTRUCTIONS
This chapter contains the instructions to operate the CRS M3.
5.1 CRS M3 Cabinet
5.1.1 Replace a used Filter Element of the Twin filter
A used filter element must be replaced in between two scheduled cluster
cleanings.
The CRS M3 generates an alarm 30 minutes before the next scheduled
cluster cleaning. If the filter is not replaced before the next scheduled cluster
cleaning and there is no clean filter, then the CRS M3 does not switch to the
other filter during the main cleaning.
1. On the CRS M3 cabinet select a cluster with the button (5).
Figure 13. CRS M3 control panel
KEY:
1. Milk tank selection button - 2. Tank driver procedure button - 3. Partial milk collection
button - 4. Main tank valve button - 5. Cluster selection button - 6. Twin filter reset button -
7. Alarm buzzer mute button - 8. CRS M3 status LED
2. Examine the LEDs of the twin filter (6): the red LED(s) shows the filter
element(s) that must be replaced.
3.
Replace the filter element of the applicable filter:
1.
Hold the cap (2) of the filter and remove the tri-clamp (1).
Operating Instructions 5-1
PDF of the English original HTML, 5.1004.8514.0 -

Table of Contents