6. TROUBLESHOOTING
6.1 Status LED on CRS M3 Cabinet flashes
If the status LED (8) on the CRS M3 cabinet flashes:
Figure 21. CRS M3 control panel
KEY:
1. Milk tank selection button - 2. Tank driver procedure button - 3. Partial milk collection
button - 4. Main tank valve button - 5. Cluster selection button - 6. Twin filter reset button -
7. Alarm buzzer mute button - 8. CRS M3 status LED
1. Open the CRS M3 web interface (page 5‑9).
2. In the tab 'Farm overview' > field 'Device info' examine the text behind
'System check:'.
3.
If the text is not 'OK', make a note of the text message and contact
your local Lely service provider.
Text Action
'OK' None (the system operates correctly)
'MODALARM' Call your local Lely service provider
'MEMORY' Call your local Lely service provider
'NOVRAM' Call your local Lely service provider
'PARAM' Call your local Lely service provider
'CONFIG' Call your local Lely service provider
'UPGRADE' Call your local Lely service provider
'INPUT' Call your local Lely service provider
6.2 Cluster Indicator LED on CRS M3 Cabinet flashes
If the cluster indicator LED (5) flashes:
Troubleshooting 6-1
PDF of the English original HTML, 5.1004.8514.0 -