Troubleshooting 7-1
7 Troubleshooting
Problem Possible cause
One sample bottle not filled.
Milk yield too low.
Examine the related milk yield.
Milk delivery tube kinked/blocked.
Clean the tube.
Milk frozen.
Keep the control room frost-free.
Sample volume too low.
Filling time too short.
Change the filling time.
Shuttle sampling device installed too high.
Place the Shuttle sampling device on the
control room floor.
Filler pipe too long.
Modify the volume of sample taken (see
Examine if the Float Chamber Contains the
Correct Volume).
The milk delivery tube is not fully open,
because the tube has been pinched too long in
the built-in sampling device valve.
Replace the tube.
One sample bottle too full.
The milk deliver tube has not been led through
the valve of the built-in sampling unit of the
robot.
Feed the tube through the valve.
Serious contamination of spoon.
Thoroughly clean the spoon (see Service
after Use).
The spoon has become jammed. The milk has
been dispensed beside the sample bottle.
Examine if the tube runs freely (see Examine
the Spoon).
Examine if the small roller in the hook of the
spoon can spin freely (see Examine the
Spoon).