5.1501.8502.0 A
Troubleshooting 7-1
7 Troubleshooting
Problem Possible cause
One sample bottle not filled.
• Milk yield too low.
• Examine the related milk yield.
• Milk delivery tube kinked/blocked.
• Clean the tube.
• Milk frozen.
• Keep the control room frost-free.
Sample volume too low.
• Filling time too short.
• Change the filling time.
• Shuttle sampling device installed too high.
• Place the Shuttle sampling device on the
control room floor.
• Filler pipe too long.
• Modify the volume of sample taken (see
Examine if the Float Chamber Contains the
Correct Volume).
• The milk delivery tube is not fully open,
because the tube has been pinched too long in
the built-in sampling device valve.
• Replace the tube.
One sample bottle too full.
• The milk deliver tube has not been led through
the valve of the built-in sampling unit of the
robot.
• Feed the tube through the valve.
•
• Serious contamination of spoon.
• Thoroughly clean the spoon (see Service
after Use).
•
• The spoon has become jammed. The milk has
been dispensed beside the sample bottle.
• Examine if the tube runs freely (see Examine
the Spoon).
• Examine if the small roller in the hook of the
spoon can spin freely (see Examine the
Spoon).