50 NE1032T Installation Guide
Installing the Air-Duct Option
TheNE1032Tsupportsanoptional1Uairducttomaximizeairflowconditionsina
19”rack.
Theair‐ductoptionisonlysupportedwhentheswitchisinstalledona4‐postrack
mountkitbasis.Iftheswitchisinstalledonarackusingdefault2‐postrackmount
kit,itwillnotsupporttheair‐ductoption.
Forinformationonremovinganinstalled1Uair‐ductoption,see“Removingthe
Air‐DuctOption”onpage 74.
Thefollowingtableliststhepartsincludedwiththeair‐ductoptionkit.
Attention:
Therack‐mountingframemaynotbeabletosupporttheweightofthe
networkingswitchwithonlythefrontpostmountingbrackets(2‐postapplication).
Iftheswitchhasanundesirableamountofsag,itisrecommendedtousea4‐post
mountingkit.
Table 12. Air‐ductOptionKitparts
Item Number Description Quantity
1Cabletie 4
21UDuctsleeve(long) 1
3 Mountingbracket(left) 1
4 Mountingbracket(right) 1
5Foamcarrierassembly 2
6M3.5screws 6
1
6
5