Note: If the server is configured for RAID operation through a ThinkSystem RAID adapter, you might have to
reconfigure your disk arrays after you install drives. See the ThinkSystem RAID adapter documentation for
additional information about RAID operation and complete instructions for using ThinkSystem RAID adapter.
Demo video
Watch the procedure on YouTube
Chassis air baffle replacement
Follow instructions in this section to remove or install the chassis air baffle.
Remove the chassis air baffle
Follow instructions in this section to remove the chassis air baffle.
About this task
Attention:
Go over
“Installation Guidelines” on page 137 to ensure that you work safely.
Turn off the server and peripheral devices and disconnect the power cords and all external cables (see
“Power off the server” on page 12).
If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the top cover,
or remove the server from the rack.
Procedure
Step 1. Make preparations for this task.
a. Remove the top cover (see
“Remove the top cover” on page 240).
b. Remove both PCIe riser cages (see
“Remove a 4U PCIe riser cage” on page 255).
Step 2. Lift the chassis air baffle to remove it from the server.