Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05 141
7 Drive application
7.3 Setting parameters (short overview)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.5.3 Terminals 11
7.5.4 Terminals 16
Connection Assignment Connection Assignment
RFR LA_NCtrl.bFailReset A1U LA_NCtrl.nMainSetValue_a
10 V 100 % reference speed (C011
)
DI1 LA_NCtrl.bSetSpeedCcw
DI2 LA_NCtrl.bSetDCBrake
DI3 LA_NCtrl.bMPotUp NO, COM LA_NCtrl.bDriveFail
DI4 LA_NCtrl.bMPotDown DO1 LA_NCtrl.bDriveReady
X101
NO
COM
GND
A1U
AR
RFR
DI1
DI2
DI3
DI4
24E
DO1
12I
X4
+
Speed setpoint
Enable controller / reset error message
Direction of rotation CCw
Manual DC-injection braking (DCB)
increase speed
decrease speed
External supply 24 V DC
Motor potentiometer
DriveFail
DriveReady
Connection Assignment Connection Assignment
RFR LA_NCtrl.bFailReset A1U LA_NCtrl.nMainSetValue_a
10 V 100 % reference speed (C011
)
DI1 LA_NCtrl.bJogSpeed1
DI2 LA_NCtrl.bJogSpeed2
DI3 LA_NCtrl. bRLQCw NO, COM LA_NCtrl.bDriveFail
DI4 LA_NCtrl. bRLQCcw DO1 LA_NCtrl.bDriveReady
X101
NO
COM
GND
A1U
AR
RFR
DI1
DI2
DI3
DI4
24E
DO1
12I
X4
+
Speed setpoint
Enable controller / reset error message
Selection of fixed setpoint 1/3
Selection of fixed setpoint 2/3
Cw rotation - quick stop
CCw rotation - quick stop
External supply 24 V DC
DriveFail
DriveReady