10 Parameter reference
10.2 Parameter list | C00158
259
Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00158
Parameter | Name:
C00158 | Cause for controller inhibit
Data type: UNSIGNED_16
Index: 24417
d
= 5F61
h
Bit-coded display of the cause/source of controller inhibit
Display area (min. hex value | max. hex value)
0x0000 0xFFFF
Value is bit-coded:
Bit 0 Terminal controller enable
Bit 1 CANDriveControl
Bit 2 Reserved
Bit 3 SwitchOn
Bit 4 Application
Bit 5 Device command
Bit 6 Error response
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 AutoStartLock
Bit 11 Motor parameter identification
Bit 12 Reserved
Bit 13 DCB-IMP
Bit 14 Reserved
Bit 15 Reserved
Read access Write access CINH PLC STOP No transfer COM MOT