5 Motor control (MCTRL)
5.6 Parameterisable additional functions
98
Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Explanation of the automatic DC-injection braking function by means of an example
[5-4] Example 1: Signal characteristic for automatic DC-injection braking of a drive without speed feedback
Speed setpoint
Actual speed value of the motor
Output current of the controller
Pulse inhibit
DC-injection braking is active
The motor rotates at a specified
speed. The current adjusts itself to
the load, see .
The DC braking current set in
C036
is injected.
After the hold time (C106) has
expired, a pulse inhibit is set.
0
1
2
3
4
C0107
C00036
C00019