EasyManua.ls Logo

Lenze 9325 - Page 122

Lenze 9325
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration
7-5
SHB9300CRV EN 2.0
7.3.2 Elements of a function block
FCNT1-CLKUP
C1102/1
C1102/2
FCNT1-LOAD
C1102/3
C1104/3
FCNT1-OUT
FCNT1
C1101/1
C1101/2
C1103/2
C1103/1
C1104/2
FCNT1-LD-VAL
FCNT1-CLKDWN
C1104/1
C1100
CTRL
FCNT1-CMP-VAL
FCNT1-EQUAL
Input symbol
Configuration code
Display code
Function
Input name Name of the function block
Output name
Output symbol
Parameterization code
Fig. 7-1 Structure of a FB using the example of FCNT1
Name of the FB
Identifies the FB unambigeously. FBs with the same function are distinguished by a number behind
their names.
Every FB is defined by a selection number. The input of the selection number into the processing
table is always required for the calculation of the FB.
(
&
7-14) . The selection numbers are listed in
selection list 5.
(
&
7-323) .
Example:
(FCNT1, see Fig. 7-1)
l
FCNT1 selection number 6400 (selection list 5).
Input symbol
Designates the signal type which is allowed as signal source for this input.
(
&
7-4)
Note!
You cannot configure inputs which are not linked.
Input name
Consists of the FB name and a designation. Inputs with the same function are distinguished by a
number behind their designations.
Configuration code
Configures the input with a signal source (e.g. terminal signal, control code, output of a FB, ¡).
Inputs with identical codes are distinguished by the subcode. The subcode is attached to the code
(Cxxxx/1).These codes are configured by their subcodes.
It is not possible to connect an input with several signal sources.
Show/Hide Bookmarks

Table of Contents