EasyManua.ls Logo

Lenze 9325 - Loading of the Ramp Generator; Ramp Generator (RFG)

Lenze 9325
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function block library
7-199
SHB9300CRV EN 2.0
7.6.65 Ramp generator (RFG)
Purpose
The ramp generator limits the rise of signals.
C0671
C0672
C0676/1
RFG1
RFG1-OUT
RFG1-IN
C0676/2
1
0
RFG1-SET
C0677
RFG1-LOAD
C0673
C0674
C0675
Fig. 7-163 Ramp generator (RFG1)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
RFG1- IN a C0676/1 dec [%] C0673 1 1000 -
RFG1- SET a C0676/2 dec [%] C0674 1 1000 -
RFG1- LOAD d C0677 - C0675 2 1000 -
RFG1- OUT a - - - - - -
Function
l
Calculation and setting of the times T
ir
and T
if
l
Loading of the ramp generator
Show/Hide Bookmarks

Table of Contents