EasyManua.ls Logo

Lenze 9325 - Output of a Speed Signal

Lenze 9325
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function block library
7-137
SHB9300CRV EN 2.0
7.6.43.1 Enable of the FIXSET1 setpoints
Number of required fixed setpoints Number of the inputs to be assigned
1 at least 1
1 ... 3 at least 2
4 ... 7 at least 3
8 ... 15 4
Decoding table of the binary input signals:
Output signal
FIXSET1-OUT =
1st input
FIXSET1-IN1
Input
FIXSET1-IN2
3rd input
FIXSET1-IN3
4th input
FIXSET1-IN4
FIXSET1-AIN 0 0 0 0
C0560/1 1 0 0 0
C0560/2 0 1 0 0
C0560/3 1 1 0 0
C0560/4 0 0 1 0
C0560/5 1 0 1 0
C0560/6 0 1 1 0
C0560/7 1 1 1 0
C0560/8 0 0 0 1
C0560/9 1 0 0 1
C0560/10 0 1 0 1
C0560/11 1 1 0 1
C0560/12 0 0 1 1
C0560/13 1 0 1 1
C0560/14 0 1 1 1
C0560/15 1 1 1 1
Show/Hide Bookmarks