7.6.68 Switching points (SPC)
Two function blocks (SPC1, SPC2)are available.
Purpose
Switches an output signal, if the drive operates within a defined range (cam switch, control of
injection nozzles).
SPC1
SPC1
C 1641/1
C 1641/2
C 1641/3
C 1641/4
C 1641/5
C 1641/6
C 1641/7
C 1641/8
C 1641/9
C 1642/1
SPC1-STAT1
SPC1-STAT2
SPC1-STAT3
SPC1-STAT4
SPC1-STAT5
SPC1-STAT6
SPC1-STAT7
SPC1-STAT8
C 1641/10
C 1641/11
C 1641/12
C 1641/13
C 1641/14
C 1641/15
C 1641/16
C 1645
VTPOSC
SPC1-L-IN
IN 1 -1
IN 1 -2
IN 2 -1
IN 2 -2
IN 3 -1
IN 3 -2
IN 4 -1
IN 4 -2
IN 5 -1
IN 5 -2
IN 6 -1
IN 6 -2
IN 7 -1
IN 7 -2
IN 8 -1
IN 8 -2
C 1644/1
C 1640/1
SPC1-RESET
C 1643/1
FCO D E
C 1476/X
FCO D E
C 1477/X
FCO D E
C 0474/X
VTPOSC
No 1 - 10
Fig. 7-166 Function block SPC1
Signal
Source Note
Name Type DIS DIS format CFG List
SPC1-L-IN ph C1644/1 dec [inc] C1642/1 3 65536 inc = 1 rev.
SPC1-RESET d C1643/1 bin C1640/1 2 -
SPC1-STAT1 d - - - - -
SPC1-STAT2 d - - - - -
SPC1-STAT3 d - - - - -
SPC1-STAT4 d - - - - -
SPC1-STAT5 d - - - - -
SPC1-STAT6 d - - - - -
SPC1-STAT7 d - - - - -
SPC1-STAT8 d - - - - -
Show/Hide Bookmarks