Function block library
7-113
SHB9300CRV EN 2.0
7.6.32.4 Encoder simulation of the resolver
Set C0540 = 2 or C0540 = 3 (depending on the desired generation of the zero track).
l
The function is used if a resolver is connected to X7.
l
The encoder constant for output X10 is set under C0030.
Generate zero pulse in resolver zero position (C0540 = 2)
The output of the zero pulse referring to the motor depends on how the resolver is attached to the
motor.
l
The zero pulse can be shifted by +360 under C0545 (65536 inc = 360°).
Generate zero pulse externally (C0540 = 3)
An artificail zero pulse can be generated for the output frequency.
l
Set input DFOUT-SYN-RDY to HIGH.
l
A LOW-HIGH edge at terminal X5/E5 generates the zero pulse 360° later.
Then, a zero pulse is generated every 360 according to C0030.
l
The zero pulse can be shifted by +360 under C0545 (65536 inc = 360°).
7.6.32.5 Direct output of X8 (C0540 = 4)
l
The input signal at X8 is amplified electrically and output directly.
l
The signals depend on the assignment of input X8.
l
C0030 and C0545 have no function.
l
The zero track is output only if it is connected to X8.
7.6.32.6 Direct output of X9 (C0540 = 5)
l
The input signal at X9 is amplified electrically and output directly.
l
The signals depend on the assignment of input X9.
l
C0030 and C0545 have no function.
l
The zero track is output only if it is connected to X9.