Configuration
7-259
SHB9300CRV EN 2.0
7.7.3.11 Motor phase failure monitoring LP1
Purpose
Protects the motor.
MONIT
MONIT-LP1
I
motor
const
Fig. 7-204 Motor phase failure monitoring LP1
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
I
MOTOR
- - - - - - -
MONIT-LP1 d - - - - - -
Function
This monitoring will be activated when a cable in one of the motor phases is interrupted.
Note!
It is also activated if the motor winding is interrupted.
Features:
l
LECOM No.: 32
l
Reaction: TRIP (unchangeable)