EasyManua.ls Logo

Lenze 9325 - Filter Time Constant

Lenze 9325
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function block library
7-211
SHB9300CRV EN 2.0
Function
l
The filter time constant is selected under C1659.
This setting is valid for SPC2-STAT1 ... SPC2-STAT4.
Assignment of code and filter time constant
Code Value Filter time constant
C1659
0 Off
C
1
6
5
9
1 1ms
2 2ms
4 4ms
8 8ms
16 16 ms
Note!
The correct setting can only be found by testing. In general:
The lower the resolution of the actual position encoder and the lower the travel speed, the higher the
filter time constant.
Show/Hide Bookmarks

Table of Contents

Related product manuals