EasyManua.ls Logo

Lenze 9325 - Synchronizing on Zero Track or Touch Probe

Lenze 9325
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function block library
7-120
SHB9300CRV EN 2.0
Speed-proportional phase setting
Leading or lagging of the phase with rising speed.
l
Enter a suitable setting in increments under code C0253.
l
The set phase offset is reached at 15000 rpm of the drive (linear relationship).
7.6.34.3 Synchronizing on zero track or touch probe
The synchronization is selected under C0532.
l
C0532 = 1, zero pulse
zero track of digital frequency input X9 and zero track by the feedback system set under
C0490 (not for resolver evaluation).
l
C0532 = 2, Touch probe
via terminals X5/E4 (actual pulse) and X5/E5 (set pulse).
l
C0532 = 3, zero pulse (setpoint) and TOUCH-PROBE (actual value)
Zero track from the digital frequency input X9 for the setpoint and touch probe initiator via
terminal X5/E4 for the actual value.
Touch probe initators can have delay times which cause a speed-dependent phase offset.
l
Set correction value for the phase offset under C0429.
l
Formula for correction value at C0429:
Correction value at C0429
16384
ô
correction value
l
Please obtain the values from the data sheet of the initiator or contact the manufacturer.
Stop!
When the synchronization via terminals X5/E4 and X5/E5 (C0532 = 2) is activated, ensure that no
other control signals are taken from these terminals. If the configuration is changed under C0005,
the terminals are assigned to a basic setting.
Synchronization mode
For the synchronization, different modes are available which can be set under C0534.
C0534 Synchronization mode Note
0 inactive function inactive
1 continuous synchronization with correction in the shortest
possible way
2 continuous synchronization with correction in the shortest
possible way
after a LOW-HIGH signal to DFSET-0-pulse, the zero track is
synchronized once
10 single synchronization, a phase deviation is corrected in the
shortest possible way
after a LOW-HIGH signal to DFSET-0-pulse, the zero track is
synchronized once
11 single synchronization, a phase deviation is corrected in CW
direction
after a LOW-HIGH signal to DFSET-0-pulse, the zero track is
synchronized once
12 single synchronization, a phase deviation is corrected in CCW
direction
after a LOW-HIGH signal to DFSET-0-pulse, the zero track is
synchronized once
13 single synchronization, a phase difference is determined between
setpoint pulse and actual pulse and is corrected to the
corresponding direction of rotation according to the sign
after LOW-HIGH signal at DFSET-0-Pulse the zero track is
synchronized once
Show/Hide Bookmarks

Table of Contents