EasyManua.ls Logo

Lenze 9325 - Page 260

Lenze 9325
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function block library
7-143
SHB9300CRV EN 2.0
Signal Source Note
Name Type DIS DIS format CFG List Lenze
MCTRL-PHI-SET ph C0908 dec [inc] C0894 3 1000 Input phase controller for difference between
set and actual phase
MCTRL-N-SET a C0906/1 dec [%] C0890 1 5050 Input speed setpoint
MCTRL-M-ADD a C0906/2 dec [%] C0891 1 1000 Additional torque setpoint or torque setpoint
MCTRL-LO-MLIM a C0906/3 dec [%] C0892 1 5700 Lower torque limit in % of C0057
MCTRL-HI-MLIM a C0906/4 dec [%] C0893 1 19523 Upper torque limit in % of C0057
MCTRL-PHI-LIM a C0906/5 dec [%] C0895 1 1006 Influence of the phase controller in % of
nmax C0011
MCTRL-N2-LIM a C0906/6 dec [%] C0896 1 1000 Lower speed limit for speed limit
MCTRL-FLDWEAK a C0906/7 dec [%] C0898 1 1006 Motor excitation
MCTRL-I-SET a C0906/8 dec [%] C0901 1 1006 Input to set the I-component of the speed
controller
MCTRL-P-ADAPT a C0906/9 dec [%] C0903 1 1006 Influence in % on VP of C0254; the absolute
value (without sign)is processed
MCTRL-PHI-ON d C0907/1 bin C0897 2 1000 HIGH = Activate phase controller
MCTRL-N/M-SWT d C0907/2 bin C0899 2 1000 LOW= speed control active
HIGH = torque control active
MCTRL-QSP d C0907/3 bin C0900 2 10250 HIGH = Drive performs QSP
MCTRL-I-LOAD d C0907/4 bin C0902 2 1000 HIGH = I component of the n-controller is ac-
cepted by MCTRL-I-SET
MCTRL-PHI-ACT phd - - - - -
MCTRL-PHI-ANG ph - - - - - 65536 inc = one revolution
MCTRL-NACT a - - - - - in % of nmax (C0011)
MCTRL-PHI-ANA a - - - - - Actual phase as analog signal
90 degree = 100%
MCTRL-MACT a - - - - - in % of Mmax (C0057)
MCTRL-MSET2 a - - - - - in % of Mmax (C0057)
MCTRL-NSET2 a - - - - - in % of nmax (C0011)
MCTRL-DCVOLT a - - - - - 100% = 1000V
MCTRL-QSP-OUT d - - - - - HIGH = Drive performs QSP
MCTRL-MMAX d - - - - - HIGH = Speed controller operates within its
limit
MCTRL-IMAX d - - - - - HIGH = Drive operates at its current limit
C0022
MCTRL-IACT a - - - - - -