EasyManua.ls Logo

Lenze 9325 - Page 319

Lenze 9325
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function block library
7-202
SHB9300CRV EN 2.0
Connection proposal:
RFGPH1-OUT
RFGPH1
C 1408/1
RFGPH1-RFG-0
RFGPH1-IN
RFGPH1-RFG-I=O
CTRL
RFGPH1-DFIN
C 1402/1
C 1400/3
C 1401/3
C 1404/1
C 1403/1
C 1405/1
RFGPH1-DIST
C 1402/2
C 1403/2
RFGPH1-T/DIST
C 1400/2
C 1401/2
RFGPH1-RESET
C 1400/1
C 1401/1
CDATA-XOFFS
FIXED0
C 1476/1
FCO D E
DIGIN1
The inputs not used must not be assigned.
Change phase/position through a defined speed (-T/DIST = LOW)
Inputs for parameter setting:
l
FCODE C1476/1 = 5 m-units (position)
l
C1408/1 = 200.0 rpm
The drive traverses to the target position with a master value speed of 200 rpm.
Control:
l
X5/E1 = HIGH
CDATA-XOFFS is traversed to 5 m-units at n = 200 rpm
l
X5/E1 = LOW
CDATA-XOFFS is traversed to 0 m-units at n = 200 rpm
l
The time required to reach the position results from the physical parameters selected.
W
W
5)*3+5)*
5)*3+,1
5)*3+287
&
&&
Change phase/position through a defined path (-T/DIST = HIGH)
Show/Hide Bookmarks

Table of Contents