EasyManua.ls Logo

Lenze 9325 - Page 410

Lenze 9325
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration
7-289
SHB9300CRV EN 2.0
7.9 Code table
How to read the code table:
Column Abbreviation Meaning
Code C0039
1
2
¡
14
15
Code C0039
Subcode 1 of code C0039
Subcode 2 of code C0039
¡
Subcode 14 of code C0039
Subcode 15 of code C0039
[C0005] Parameter value of the code can only be modified when controller is inhibited
LCD Keypad LCD
l
DIS: ... Only display
l
CFG: ... Configured value is indicated on the LCD of the keypad
l
All other are parameter values
Lenze Factory setting of the code
* The column Important contains further information
Selection 1{1%}99Minimum value {smallest step/unit} maximum value
IMPORTANT - Additional, important explanation of the code
&
7-289 Reference on page with further information on the code.
Code LCD
Possible settings
Important
C
o
d
e
L
C
D
Lenze Selection
I
m
p
o
r
t
a
n
t
ABS
[C0661] CFG: IN 1000 FIXED 0 %
@
Selection list 1 Analog input absolute value generator
C0662 DIS: C0661 -199.99 {0.01 %} 199.99 Display of C0661
ADD
[C0610]
1
2
3
CFG: IN1
CFG: IN2
CFG:IN3
1000 FIXED0%
@
Selection list 1 Adds inputs IN1, IN2 and IN3
C0611 DIS: C0610/1 ... 3 -199.99 {0.01 %} 199.99
AIF
C0136
3
DIS: CTRLWORD Control word in AIF-IN
C0151 DIS: FDO (DW) Output signals configured with C0116 Hexadecimal signal assignment of the free
digital outputs.
l
Binary interpretation indicates the bit
states
[C0850]
1
2
3
CFG: OUT.W1
CFG: OUT.W2
CFG: OUT.W3
1000 FIXED 0 %
@
Selection list 1 Configuration process output words for au-
tomation interface AIF (X1)
[C0851] CFG: OUT.D1 1000 FIXED 0INC
@
Selection list 3 Configuration 32-bit phase information
C0852 Type OUT.W2 0 0 Analog signal
1 Digital 0-15
2 Low phase
3 High phase
Configuration process output word 2 for au-
tomation interface AIF (X1)
C0853 Type OUT.W3 0 0 Analog signal
1 Digital 16-31
2 High phase
Configuration pocess output word 3 for au-
tomation interface AIF (X1)
C0854 Type OUT.W1 0 0 Analog signal
3 D2: Low phase
Configuration process output word 1 for au-
tomation interface AIF (X1)
C0855 DIS: IN (0-15)
DIS: IN (16-31)
Bit 00 {1} Bit 15 Process input words hexadecimal for auto-
mation interface X1
C0856
1
2
3
DIS: IN.W1
DIS: IN.W2
DIS: IN.W3
-199.99 {0.01%} 199.99 Process input words decimal