Configuration
7-306
SHB9300CRV EN 2.0
Code ImportantPossible settingsLCDCode Important
SelectionLenze
LCD
C0052 MCTRL-Umot 0 {1 V} 800 Actual motor voltage
C0053 UG-VOLTAGE 0 {1 V} 900 DC-bus voltage
C0054 IMot 0.0 {0.1 A} 300.0 Actual motor current
C0056 MCTRL-MSET2 -150.00 {0.01 %} 150.00 Torque setpoint (output of the speed controller)
C0057 Max Torque 0 {1 Nm} 400 Maximum possible torque of the drive configuration
l
depends on C0022, C0086
C0070 Vp speed-CTRL * 0.0 {0.5} 255.0 V
pn
speed controller
Å
depends on C0086
l
Change of C0086 resets value to the assigned
default setting
C0071 Tn speed-CTRL * 1.0 {0.5 ms} 600.0 T
nn
speed controller
>512 ms switched off
Å
depends on C0086
l
Change of C0086 resets value to the assigned
default setting
C0072 Td speed-CTRL 0.0 0.0 {0.1 ms} 32.0 T
dn
speed controller
C0075 Vp curr-CTRL 0.35 0.00 {0.01} 15.99 V
pi
current controller
C0076 Tn curr-CTRL 1.8 0.5 {0.1 ms} 1999.0 T
ni
current controller
2000 ms switched off
C0077 Vp fie ld- CTRL 0.25 0.00 {0.01} 15.99 V
pF
field controller
C0078 Tn field-CTRL 15.0 1.0 {0.5 ms} 7999.0 T
nF
field controller
8000 ms switched off
[C0081] Mot power * 0.01 {0.01 kW} 150.00 Rated motor power according to nameplate
Å
depends on C0086
l
Change of C0086 resets value to the assigned
default setting
l
Change of C0081 sets C0086 = 0
[C0084] Mot Rs * 0.00 {0.01
} 100.00 Stator resistance of the motor
Å
depends on C0086
l
Change of C0086 resets value to the assigned
default setting
[C0085] Mot Ls * 0.00 {0.01} 200.00 Motor leakage inductance
Å
depends on C0086
l
Change of C0086 resets value to the assigned
default setting
[C0086] Mot type * Selection motor type
Å
depends on the controller
l
Change of C0086 resets C0006, C0022, C0070,
C0071, C0081, C0084, C0085, C0087, C0088,
C0089, C0090, C0091 to the assigned default set-
ting
0 COMMON no Lenze motor
New generation of Lenze asynchronous servo motors
integrated temperature monitoring via resolver or encoder cable
l
The temperature monitoring via resolver or encoder cable is automatically activated, i.e.:
C0583 = 0
C0584 = 2
C0594 = 0