Parameter Name / value range / [default seng] Info
0x400C:002
(P593.02)
Process output data: LECOM status word
(Process data OUT: LECOM stat. word)
•
Read only
Mappable status word with bit assignment in compliance with code
C150 of the 8200 Lenze inverter.
Bit 0 Acve parameter set (0 = set 1 or 3; 1 = set 2
or 4)
Bit 1 Power secon inhibited
Bit 2 Current or Torque limit reached
Bit 3 Frequency setpoint reached
Bit 4 Ramp generator (input = output)
Bit 5 Frequency < frequency threshold
Bit 6 Actual frequency = 0
Bit 7 Inverter disabled
Bit 8 Coded status bit 0
Bit 9 Coded status bit 1
Bit 10 Coded status bit 2
Bit 11 Coded status bit 3
Bit 12 Overtemperature warning
Bit 13 DC-bus overvoltage
Bit 14 Rotaonal direcon reversed
Bit 15 Ready for Operaon
Conguring the network
Predened process data words
Lenze LECOM prole
195