Parameter Name / value range / [default seng] Info
0x2DAE:003
(P140.03)
Sequencer diagnoscs: Step me remaining
(Sequencer diag: StepTime remain)
•
Read only: x.x s
•
From version 03.00
Display of the residual me for the current step.
0x2DAE:004
(P140.04)
Sequencer diagnoscs: Steps complete
(Sequencer diag: Steps complete)
•
Read only
•
From version 03.00
Display of the number of steps that have been made since the start of
the sequence.
0x2DAE:005
(P140.05)
Sequencer diagnoscs: Steps remaining
(Sequencer diag: Steps remain)
•
Read only
•
From version 03.00
Display of the residual number of steps unl the current sequence is
completed. This includes the current step.
0x2DAE:006
(P140.06)
Sequencer diagnoscs: Acve sequence
(Sequencer diag: Acve sequence)
•
Read only
•
From version 03.00
Display of the acve sequence.
•
0 ≡ no sequence acve.
0x2DAE:007
(P140.07)
Sequencer diagnoscs: Acve segment
(Sequencer diag: Acve segment)
•
Read only
•
From version 03.00
Display of the acve segment.
•
0 ≡ no sequence acve.
•
255 ≡ nal sequence acve.
0x2DAE:008
(P140.08)
Sequencer diagnoscs: Relave sequence me
remaining
(Sequencer diag: SeqTime remain %)
•
Read only: x %
•
From version 03.00
Display of the residual me of the sequence in [%].
0x2DAE:009
(P140.09)
Sequencer diagnoscs: Absolute sequence me
remaining
(Sequencer diag: SeqTime remain)
•
Read only: x.x s
•
From version 03.00
Display of the residual me of the sequence in [s].
Related topics
4Sequencer ^ 325
4Sequencer control funcons ^ 402
6.2.10 Device idencaon
The following parameters show some general informaon about the inverter.
Parameter Name / value range / [default seng] Info
0x2000:001
(P190.01)
Device data: Product code
(Device data: Product code)
•
Read only
Product code of the complete device.
Example: "I51AE155D10V10017S"
0x2000:002
(P190.02)
Device data: Serial number
(Device data: Serial number)
•
Read only
Serial number of the complete device.
Example: "0000000000000000XYZXYZ"
0x2000:004
(P190.04)
Device data: CU rmware version
(Device data: CU rmware ver.)
•
Read only
Firmware version of the control unit.
Example: "01.00.01.00"
0x2000:005
(P190.05)
Device data: CU rmware type
(Device data: CU rmware type)
•
Read only
Firmware type of the control unit.
Example: "IOFW51AC10"
0x2000:006
(P190.06)
Device data: CU bootloader version
(Device data: CU bootlder ver.)
•
Read only
Bootloader version of the control unit.
Example: "00.00.00.13"
0x2000:007
(P190.07)
Device data: CU bootloader type
(Device data: CU bootlder type)
•
Read only
Bootloader type of the control unit.
Example: "IOBL51AOnn"
0x2000:008
(P190.08)
Device data: Object directory version
(Device data: OBD version)
•
Read only
Example: "108478"