Conguring the write access protecon with the keypad
The write access protecon is acvated by dening PIN1 in P730.00 and/or PIN2 in P731.00
(depending on the desired conguraon of the write access protecon).
In the following example, the write access protecon is congured in such a way that a write
access to the favorites only is possible or (when knowing PIN) to all parameters. This congu-
raon only requires the denion of PIN1 (here: "123").
MAN
AUTO SET
LOC REM
MAN AUTO SETLOC REM
Addit. functions
MAN AUTO SETLOC REM
MAN AUTO SETLOC REM
P730.00
MAN AUTO SETLOC REM
MAN AUTO SETLOC REM
1.
2.
3.
4.
5.
7.
MAN AUTO SETLOC REM
P730.00
6.
VEL:FLEX:AIN1
Device commands
Favorites
Protection PIN1
0 0 0 S T O P
G R O U P O O
G R O
U
P O 7
O P 7 O O x x
O P 7 3 O O O
O
2 3
O O O O O O
O O O O 1
Dening PIN1:
1.Use the key in the operang mode to navigate to the
parameterisaon mode one level below.
You are now in the group level.
Note: By using the key you can navigate one level
upwards again anyme.
2.Use the navigaon key to select group 7.
3.Use the key to navigate to one level below.
You are now in the parameter level of the group selec-
ted.
4.Use the navigaon key to select the P730.00 param-
eter.
5.Use the key to navigate to one level below.
You are now in the eding mode.
6.Use the navigaon key to set PIN1 to the value
"123".
7.Use the key to accept the changed seng.
The eding mode is exited.
Note: The congured access protecon only gets eec-
ve aer the parameter group is quit.