Parameter Name / value range / [default seng] Info
0x4040
(P820.00)
Start of sequence mode
(StartOfSeq. mode)
From version 03.00
Selecon of the acon aer the motor has been stopped and restarted
or aer the motor has been restarted aer an error occurred.
0 Restart sequencer The currently selected sequence is restarted.
1 Restart current segment The current segment of the selected sequence is restarted.
2 Connue current segment The current segment of the selected sequence is connued (just like
aer a break).
3 Start next segment The next segment of the selected sequence is started.
4 No acon For debugging purposes: The sequence is connued to be processed
(including output states) even if the motor is stopped.
Related topics
4Sequencer control funcons ^ 402
4Sequencer diagnoscs ^ 85