Parameter Name / value range / [default seng] Info
0x2631:011
(P400.11)
Funcon list: Jog reverse (CCW)
(Funcon list: Jog reverse)
Seng can only be changed if the inverter is inhibi-
ted.
For further possible sengs, see parameter
0x2631:001 (P400.01). ^ 351
Assignment of a trigger for the "Jog reverse (CCW)" funcon.
Trigger = TRUE: Let motor rotate backward with preset 6.
Trigger = FALSE: Stop motor.
CAUTION!
The jog operaon has a higher priority than the "Run" funcon, all other
start commands and the keypad key .
If jog operaon is acve, the motor cannot be stopped with the previ-
ously menoned funcons!
However, jog operaon can be interrupted by the "Quick stop" func-
on.
Notes:
The preset value 6 can be set in 0x2911:006 (P450.06).
The stop method can be selected in 0x2838:003 (P203.03).
If "Jog foward (CW)" and "Jog reverse (CCW)" are acvated at the
same me, the motor is stopped using the stop method and jog oper-
aon must be triggered again.
Jog operaon cannot be started automacally. The "Start at power-
up" opon in 0x2838:002 (P203.02) does not apply to jog operaon.
0 Not connected
0x2631:013
(P400.13)
Funcon list: Reverse rotaonal direcon
(Funcon list: Reverse rot.dir.)
Seng can only be changed if the inverter is inhibi-
ted.
For further possible sengs, see parameter
0x2631:001 (P400.01). ^ 351
Assignment of a trigger for the "Reverse rotaonal direcon" funcon.
Trigger = TRUE: the setpoint specied is inverted (i. e. the sign is inver-
ted).
Trigger = FALSE: no acon / deacvate funcon again.
13 Digital input 3
Flexible I/O conguraon
Start / stop motor
355