Electrical installation
HighLine C control terminals
External supply voltage 24 V
6
231
EDS84ASC552 EN 10.0
X4
24O
DC 24 V
(+19.2...+28.8 V)
X4
DO1DO2
DO3
GO
GND-O
8400HLC035 8400HLC045
Fig. 6-39 Connection to an external supply voltage
Labelling Description
24O Connection for an external 24 V supply by a safely separated power supply
unit (SELV/PELV), IEC 61131-2
(required for the supply of t he digital outputs)
GO GND-O Ground reference potential for the digital outputs
Terminal data
Conductor cross-section Tightening torque
[mm
2
] [AWG] [Nm] [lb-in]
Flexible
0.2 ... 1.5
24 ... 16 - - -