EasyManua.ls Logo

Lenze L-force E84A Series - Braking Operation; Braking Operation Without Additional Measures

Lenze L-force E84A Series
308 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Braking operation
Braking o peration without additional measures
8
251
EDS84ASC552 EN 10.0
8 Braking operation
8.1 Braking operation without additional measures
DC injection brake DCB
To decelerate small masses, the ”DC injection brake DCB” function can be parameterised.
DC-injection braking enables a quick deceleration of the drive to standstill without the
need for an external brake resistor.
ƒ Code C00036 can be used to select the braking current.
ƒ The m aximum braking torque to be realised by the DC braking current amounts to
approx. 20 ... 30 % of the rated motor torque. It i s lower compared to braking action
in generator mode with external brake resistor.
ƒ Automatic DC-injection braking (Auto-DCB) improves the starting performance of
the motor when the operation mode without speed feedback is used.
Further information on the relevant parameters can be obtained from the software
manual.