11.6 Memory module
11.6.1 E84AYM10S
Name: Memory module (for StateLine/HighLine version)
Type designation: E84AYM10S (/M = 5 pcs/VPE)
Slot: MMI
The parameters of the controller are stored in the memory module.
The pluggable memory module enables a quick parameter set transfer to an identical
controller. Possible reasons for a parameter set transfer are:
ƒ Duplication of similar applications in a series of identical drives.
ƒ Restorage of an application after device replacement.
The required steps for a parameter set transfer are described in the software manual.
In order to remove the memory module, use a suitable screwdriver to lever the module out
attheupperandlowergroove. Inordertoplugin themodule,insert itinto theslot andpush
it with light pressure until end position is reached.
Stop!
The device contains components that can be destroyed by electrostatic
discharge!
Before working on the device, the personnel must ensure that they are free of
electrostatic charge by using appropriate measures.