Electrical installation
TopLine C control terminals
Encoder connection
6
240
EDS84ASC552 EN 10.0
6.9.2 Encoder connection
X8
Clock-
A Cos -
A
RefCos -
GNDGNDGND
--
Us
B Sin -
B
RefSin -
Vcc Vcc
-
---
Z +RS485 Data+
Z
-RS485 Data-
--
--Clock+
-KTY -KTY -
+KTY +KTY -
TTL
Hiper-
face
SSI
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
KTY
SIN
COS
0.5V
0.5V
RefCOS
RefSIN = 2.5V
= 2.5V
A
A
B
Z
B
Z
?
Clock-
SSP94ENCX8 b
Fig. 6-46 Wiring principle
Signalsofasin/cosencoder
Signals with CW rotation
Terminal data
Conductor cross-section Tightening torque
[mm
2
] [AWG] [Nm] [lb-in]
Flexible
0.2 ... 1.5
24 ... 16 - - -