Safety engineering
Technical data
10
281
EDS84ASC552 EN 10.0
10.7 Technical data
Supply
The inputs andoutputs are isolated and designedfor a low-voltage supplythrough a safely
separated power supply unit (SELV/PELV) of 24 V DC. P/N switching input signals and test
pulses 1 ms are permissible.
Active sensors are directly wired to the X80 terminal strip.
Passive sensors are wired to the X80 terminal strip via a switching device. The switching
device must comply with the required control category of the application.
There is no monitoring for short circuits.