Online commands
66 BCL 8 Leuze electronic
Copy parameter set
Request parameter set from the BCL 8
Command ’PC’
Description The command copies complete parameter sets.
Parameter
’03’ Copy parameters from the EEPROM into the RAM and initialize all
associated functions
'20' Copy standard parameters from the FLASH into the EEPROM and
RAM and initialize all relevant functions
’30’ Copy parameters from the RAM into the EEPROM
Acknowledg-
ment
’PSx’
x Status
'0' valid transmission
'1' invalid message
'2' invalid length of message
'3' invalid block check type
'4' invalid block check checksum
'5' invalid data length
'6' invalid message data
'7' invalid start address
'8' invalid parameter set
'9' invalid parameter type
Example ’PC20’ loads the default parameters
Command ’PR’
Description
The command requests parameter data from the BCL 8. Parameter <PS-
type> displays the parameter set from which the data is to be transmitted.
Parameter <BCC type><PS type><Start address><Data length>
Acknowledg-
ment
’PSx’
x Status
'0' valid transmission
'1' invalid message
'2' invalid length of message
'3' invalid block check type
'4' invalid block check checksum
'5' invalid data length
'6' invalid message data
'7' invalid start address
'8' invalid parameter set
'9' invalid parameter type
Example
’PR00102004’
Beginning with address 102, four (004) bytes are read out and transmitted