Online commands
Leuze electronic BCL 8 67
TNT 35/7-24V
Acknowledge parameter message
Transfer parameters
Command ’PS’
Description
The command acknowledges the received message and delivers an
acknowledgement status which indicates whether the message was valid
or invalid.
Parameter
’PSx’
x Status
'0' valid transmission
'1' invalid message
'2' invalid length of message
'3' invalid block check type
'4' invalid block check checksum
'5' invalid data length
'6' invalid message data
'7' invalid start address
'8' invalid parameter set
'9' invalid parameter type
Command ’PT’
Description
The command transmits parameter data beginning with the set address
and stores it there in an intermediate buffer. If the status indicates that fur-
ther messages follow, these are also stored in the intermediate buffer
before they are then stored under the corresponding parameter set type in
the EEPROM. The transmission can optionally occur with a block check
test of the message data.